Page 327 - 2018wd_ctr_cat
P. 327

                Part No. Features and Applications
• low cost single phase motor protection • built in anti-short cycle protection.
• detects high/low voltage conditions.
• Helps prevent rapid system recycling
Specifications
Replaces
vOLTAGE PROTEcTION
 SINGLE PHASE LINE vOLTAGE MONITORS
 • voltage: 95-270 vaC
• diversified: Cv-100-rS Cv-200-rS15 Cv-200-rS20 • watsco: eaC-401 eaC-402 eaC-403 eaC-404
        IcM491 • led indicators:
- green for normal conditions.
• output:
relay, Spdt n.c../n.o.: 5 amps
- red for fault
• Heavy duty Spdt, isolated relay output.
• Interrogation delay prevents nuisance trips.
• time delay • range:
Part No. Features and Applications
Specifications
Replaces
adj. 6-600 sec.
3 PHASE LINE vOLTAGE MONITORS - Full Performance
 • fully programmable- with lCd diagnostic
• voltage:
• diversified: aC2020 aC301 aC302
      IcM450 IcM450S •
• motorsaver 455
•SSaC qlm/qlv
• timemark 265
• wagner wpC-800
• watsco eaC-800 eaC-8000
• •
display.
easy to configure- simple pushbutton setup. easy to customize- setpoints, variables
and features are fully adjustable and may be defined by the user while in control Setup mode.
25-fault memory storage, non-volatile. Independent high and low voltage settings
- ideal for dual voltage compressor applications, Identifies front & back side faults.
reset mode: choice of auto or manual. protects against: voltage unbalance, high/low voltage, phase loss, reversal, faulty power, incorrect sequencing
and rapid short cycling,
reliable, high temperature lCd to 167 f. Simultaneous voltage display- no scrolling. line voltage programmable. universal voltage operation: 190-630 vaC
6.5" x 4.25" 1.5"
•
•
•
190-630 vaC
frequency: 50or60hz
Control: 18-240 vaC
delay on break timer: (0.1-10 min.)
                   (Spanish) • •
output:
  •
• • •
•
• relay, Spdt n.o.: 10 amps n.c.: 6 amps
PHASE LOSS & REvERSAL PROTEcTION - Ultra Low cost
 Part No. Features and Applications Specifications
• low cost 3 phase protection for single side.     • voltage:
                      • monitors for phase reversal, phase loss, inbalance % as a function of input voltage
190-600 vaC
• bright led indicators for on and fault. IcM401 • universal 3 phase input: 190-600 vaC.
• frequency: 50 or 60 hz
• Control: 18-30 vaC.
• output:
relay, Spdt n.o.: 10 amps
• Control voltage: 18-30 vaC.
• Highly reliable passive electronics.
• Ieee587 transient tested.
• epoxy coated for added protection.
• patented: u.S. patent no. 5,337,206.
• ICm401 enclosed model shown at right. • for open board model order ICm403
• 3.25"x 3" x 1.25"
Specifications
  Part No. Features and Applications
• low cost 3 phase protection for single side. • monitors for phase reversal, phase loss,
• voltage: 190-600 vaC
       inbalance % as a function of input voltage • bright led indicators for on and fault.
• frequency: 50 or 60 hz
• Control: 115 or 208/230 vaC
IcM402 • universal 3 phase input: 190-600 vaC.
• Control voltage input: 15, 208, 230 vaC.
• Highly reliable passive electronics.
• Ieee587 transient tested.
• epoxy coated for added protection.
• patented: u.S. patent no. 5,337,206.
• ICm402 enclosed model shown at right. • for open board model order ICm404
• output:
relay, Spdt n.o.: 30 amps
                  • 3.25"x 3" x 1.25" prices subject to change without notice 321 © 1971 - 2018 w.d. armstrong corp.